top of page

A test run separating dimethyl maleate and dimethyl fumerate has been performed and shown in photos.

50mg of each compound (total mass 100mg), dissolved in a small amount mixture of hexane, acetone and dichloromethane was spotted onto the plate. The plate was eluted twice with hexane:acetone=15:1, giving a very good separation. While this is expected, this also indicated that depending on how far away each component band is on TLC, one can load material amounts of 100mg and more onto the plate since in the example the plates have not quite reached full capacity.

The preparative TLC method is an alternative to preparative HPLC. HPLC methods can be more expensive and when handled improperly, contamination can occur. Prep TLC is especially suitable for applications when there is relatively a small amount of sample, and purity requirements are high, and when at the same time the researcher is looking for a quick, convenient and economic way of purification.

Preparative TLC PLC Plates Silica Gel 60 F254 20 x 20 cm Size 1 mm Thick 8/box

SKU: plc1mm
$70.00Price
Expected to ship by the end of September
  • Classic Preparative TLC Plates. Silica Gel 60 F254 type. 20x20cm plate size, 1mm (1000μm) silica layer thickness. pH 6.2-6.8, particle size 10-40 μm, pore size 60 Å. 8 glass plates per box.

Product Page: Stores_Product_Widget
bottom of page